An alert rule watches a condition. When the condition holds long enough, the rule opens an alert. The alert runs an escalation policy to notify people and channels, and opens an incident with a timeline. Manage rules on the dashboard’s Alerts page.

Rule kinds

KindFires whenCreated
CheckAn uptime check is down (or down or degraded)Automatically, one per check
HeartbeatA heartbeat is late, failed, or eitherAutomatically, one per monitor
LogThe number of matching log lines in a window crosses a thresholdBy you

You can also declare an alert by hand, for example when a customer reports a problem first. A declared alert runs an escalation policy like any other.

Check and heartbeat rules

These rules come with every check and heartbeat. You can edit or pause them.

  • Check rules fire on down by default, after the state holds for 60 seconds. Choose down or degraded to also be told about slow responses and certificates near expiry.
  • Heartbeat rules fire on late and fail straight away (the grace period is the delay). They arm only after the first ping.

Log rules

A log rule counts lines that match a query over a sliding window:

query      service:checkout level:>=error
window     5 minutes
condition  count > 20
SettingRange
QueryUp to 2,000 characters, the explorer’s syntax
Window1 to 60 minutes
Evaluated every30 seconds to 60 minutes, no longer than the window. The dashboard uses one minute.
Condition>, >=, <, <= or == a whole number from 0 to 1,000,000,000
ScopeSome projects or all, optionally limited to environments or service environments

The alert’s cause reads like “23 lines in the last 5m (> 20): service:checkout level:>=error”. Log rules are not grouped by field: one rule has at most one open alert. To alert per service, create one rule per service. Some plans do not include log alerts.

Timing

SettingMeaningDefault
Wait before starting (for)The condition must hold this long before the alert opens60 s for checks, 0 for heartbeats and log rules
Resolve afterThe condition must be clear this long before the alert resolves0 for checks and heartbeats; the window for log rules
CooldownIf the rule fires again within this time, the same alert reopens instead of a new one5 minutes

Each can be up to 24 hours.

Severity

SeverityUse for
sev1 CriticalCustomers cannot use the product
sev2 MajorA core feature is broken
sev3 MinorDegraded, with a workaround
sev4 LowCosmetic or internal only

Log rules default to sev2. A declared alert defaults to sev3.

Lifecycle

ok ──(condition holds for "for")──▶ firing ──▶ acknowledged ──▶ resolved
                                       │                            ▲
                                       └──(condition clears)────────┘
  • Firing. Escalation runs and reminders are sent.
  • Acknowledged. Someone is on it. Escalation stops.
  • Snoozed. Reminders and escalation pause for 5 minutes to 24 hours. Steps that fall due meanwhile run when the snooze ends. Snoozing again replaces the end time. The alert stays open.
  • Resolved. Either the condition cleared (recorded as recovered) or someone resolved it. If you resolve while the condition still holds, the alert opens again after the rule’s wait.

A rule has at most one open alert at a time.

Acknowledge, resolve and snooze

From the dashboard, the alert email (the Acknowledge button opens a confirmation page and acknowledges as you), Slack’s Open incident link, ZevThread’s card buttons, or the API:

# list open alerts
curl https://eu.zevsight.com/v1/alerts -H "Authorization: Bearer <API_KEY>"

# acknowledge, resolve, snooze
curl -X POST https://eu.zevsight.com/v1/alerts/<ALERT_ID>/acknowledge -H "Authorization: Bearer <API_KEY>"
curl -X POST https://eu.zevsight.com/v1/alerts/<ALERT_ID>/resolve     -H "Authorization: Bearer <API_KEY>"
curl -X POST https://eu.zevsight.com/v1/alerts/<ALERT_ID>/snooze \
  -H "Authorization: Bearer <API_KEY>" -H "Content-Type: application/json" -d '{"minutes": 30}'

Changing an alert needs a member, admin or owner, or an API key with the respond permission. Viewers and read-only keys get 403. See the Alerts API reference.